Página 1 - CJ2SERIES

Programmable Automation ControllersIntroducing the Flagship CJ2 CPU Units, with Built-in Multifunctional EtherNet Port Built-in EtherNet/IP por

Página 2

10Connecting Support Software is Now Easier and Safer.Using General-purpose Networks for Support Software Interface. Connecting to a USB or EtherNet/I

Página 3 - Key Features and Benefits

EtherNet/IP192.168.250.13 192.168.250.14 192.168.250.15The PAC name can be easily found by selecting from the list that is displayed.HUBCX-ProgrammerO

Página 4 - CJ1 Product Lineup

Previously (CJ1) CJ2CJ1 CPUOnline editingCJ2 CPUAdditional time: Approx. 8 msOnline editingAdditional time: Approx. 1 msFBSFCFB defi nitionSFC program

Página 5 - High-speed, high-capacity

13Greatly Improved Debugging Effi ciency Through Superior Data TracingHigh-speed, High-capacity Data Tracing is now possible.NEW8TimesMore capacityAmpl

Página 6 - Networks Are More Open

D100.0515D100Bit14 13 12 11 10 9876543210E0_100.03D200.00D100.05W0.00TIM100-ms timer (BCD)100-ms timer (binary)Timer numberTimer numberSet valueSet va

Página 7 - Performance

NEWOperation status:Published :Input :OutputExampleOperation start Operation stopdata [i]Symbol that indirectly specifies the element numberArray vari

Página 8 - Terminal and CJ2 CPU Unit

16 CJ-series CPU Racks A CJ-series CPU Rack consists of a CPU Unit, Power Supply Unit, Configuration Units (Basic I/O Units, Special I/O Units, and CP

Página 9 - What is Tag Access?

17System Configuration CJ-series Expansion Racks A CJ-series Expansion Rack consists of a Power Supply Unit, an I/O Interface Unit, Configuration Units

Página 10 - Easier and Safer

18External InterfaceA CJ2H CPU Unit provides three communications ports for external interfaces: a peripheral (USB) port, a serial port and an EtherNe

Página 11 - Online connection

19General SpecificationsItemCJ2H-CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIPEnclosure Mounted in a panelGrounding Less than 100 ΩCPU Rack Dimensi

Página 12 - Easier On-site Debugging

2CJ2 – Omron’s New Small, Fast & Flexible Modular Flagship PAC, with built-in EtherNet/IP and Tag Based ProgrammingThe CJ2 Programmable Automation

Página 13 - More capacity

20ItemCJ2H-CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIPUser Memory 50K steps 100K steps 150K steps 250K steps 400K steps I/O Bits 2,560

Página 14 - More Flexible Programming

21ItemCJ2H-CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIPProgramming Languages Ladder Logic (LD), Sequential Function Charts (SFC), Structured Text

Página 15 - :Published :Input :Output

22Performance SpecificationsItemCJ2H-CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIPCommunicationsLogical Ports for CommunicationsLogical Ports 8 por

Página 16 - Required Units ●

23Performance SpecificationsInternational Standards• The standards indicated in the “Standards” column are those current for UL, CSA, cULu

Página 17 - System Configuration

24Ordering InformationBasic Configuration UnitsCPU Units CJ2 CPU Units Product nameSpecificationsCurrent consumption (A)Model StandardsI/O capacity/ Mo

Página 18 - Pihl(USB) P

25Ordering InformationExpansion RacksSelect the I/O Control Unit, I/O Interface Unit, Expansion Connecting Cable, and CJ-series Power Supply Unit. CJ-

Página 19 - General Specifications

26Ordering InformationProgramming DevicesSupport Software Product name Specifications Model StandardsNumber of licensesMediaFA Integrated ToolPackage

Página 20 - Performance Specifications

27Ordering InformationBasic I/O Units Input Units Unit classificationProduct nameSpecificationsNo. of words allocatedCurrent consumption (A)Model Stan

Página 21

28Ordering InformationOutput Units Unit classificationProduct nameSpecificationsNo. of words allocatedCurrent consumption (A)Model StandardsI/O points

Página 22

29Ordering InformationI/O Units Unit classificationProduct nameSpecificationsNo. of words allocatedCurrent consumption (A)Model StandardsI/O pointsInp

Página 23

3Key Features and BenefitsLarge Memory Capacity –The CPU program memory capacity has been increased up to 400K Steps, DM has increased up to 800K while

Página 24 - Ordering Information

30Interrupt Input Units Unit classificationProduct nameSpecificationsNo. of words allocatedCurrent consumption (A)Model StandardsI/O pointsInput volta

Página 25

31Special I/O Units and CPU Bus Units Process I/O Units Isolated-type Units with Universal Inputs ●Unit classificationProduct nameInput pointsSignal

Página 26

32Ordering InformationIsolated-type Resistance Thermometer Input Units ●Unit classificationProduct nameInput pointsSignal range selectionSignal range

Página 27

33Ordering InformationAnalog Output Units ●Unit classificationProduct nameOutput pointsSignal range selectionSignal range ResolutionConversion speedAc

Página 28

34Temperature Control Units Unit classificationProduct nameSpecificationsNo. of unit numbers allocatedCurrent consumption (A)Model StandardsNo. of loo

Página 29

35 MECHATROLINK-II-compatible Position Control Units Unit classificationProduct name SpecificationsNo. of unit numbers allocatedCurrent consumption (A

Página 30

36 EtherNet Unit Unit classificationProduct nameSpecificationsNo. of unit numbers allocatedCurrent consumption (A)Model StandardsCommunicationscableCo

Página 31

37CompoNet Master Unit Unit classificationProduct nameSpecificationsNo. of unit numbers allocatedCurrent consumption (A)Model StandardsCommunicationsf

Página 32

38Dimensions (Unit: mm)Dimensions(Unit: mm)CJ2H CPU Unit6579.8 74.52.72.79066.2

Página 33

39Checking Current Consumption and Power ConsumptionAfter selecting a Power Supply Unit based on considerations such as the power supply voltage, calc

Página 34

4High-capacity data memory is in demand to meet the need for quality control for equipment and products and to provide real-time processing and collec

Página 35

OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERSSchaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.comOMRON CANADA, INC. • HEAD OFFICETo

Página 36 - • #9207 (Belden: US Company)

5Automatic User Memory RecoveryFiner memory production processes have been accompanied by problems such as bit corruption caused by cosmic rays. With

Página 37

EtherNet/IPCJ2 CPUProgrammable TerminalHost applicationData linksMessage communicationsFTPCX-OneHUBCJ2 CPU CJ1-EtherNet/IP UnitMessage communicationsD

Página 38 - CJ2H CPU Unit

Host applicationSupport SoftwareCJ1 or CJ2 CPU UnitPLCProgrammable Terminal NS SeriesFA wirelessLAN WE70Data LinksFINS MessagingFTPTime CoordinationTa

Página 39

8No Need for Memory Map Control.The CJ2 CPU Units introduce a new feature called tag access, to reduce your TCO (Total Cost of Ownership) for systems

Página 40

9The Ease of Changing Designs Makes It Simple to Add or Upgrade Equipment.There is little effect on address changes.Previously, when data was exchange