Omron SYSMAC CP CP1E-N@@D@-@ Manual do Utilizador Página 325

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 467
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 324
2-289
2 Instructions
CP1E CPU Unit Instructions Reference Manual(W483)
Data Control Instructions
2
AVG
In the following example, the content of CIO 40 is set to #0000 and then incremented by 1 each cycle.
For the first two cycles, AVG(195) moves the content of CIO 40 to D1002 and D1003. The contents of
D1001 will also change (which can be used to confirm that the results of AVG(195) has changed).
On the third and later cycles AVG(195) calculates the average value of the contents of D1002 to
D1004 and writes that average value to D1000.
D1000 0 1 1 2
D1001 1 2 8000 8001
D1002 0 0 0 3
D1003 --- 1 1 1
D1004 --- --- 2 2
CIO 40
0123
1
st
cycle 2
nd
cycle 3
rd
cycle 4
th
cycle
Average
Pointer
3 previous values of IR 40
2 Average
1
@MOV
#0000
40
+
40
#0001
40
AVG
40
#0003
D1000
CLC(41)
0.00
Vista de página 324
1 2 ... 320 321 322 323 324 325 326 327 328 329 330 ... 466 467

Comentários a estes Manuais